Marriott: Design Standards Module 14

Ventilation and Fire Protection of Commercial Cooking Operations (Kitchens). Compliance & Administration fire protection & life safety

5–10 fc (54–108 lux) at night; 20 fc (215 lux) at day. Vertical Illuminance (door face): 15 fc (161 lux) minimum for face recognition.

Module 14 devotes six pages to the shower experience. Key mandates include: marriott design standards module 14

: Alarm systems must be monitored 24/7, both on-site at a central control station and via an approved off-site monitoring service. 2. Automatic Fire Sprinkler Systems

The Marriott Design Standards, and specifically Module 14, are not merely a "nice-to-have" checklist. They are the lifeblood of the brand's commitment to safety and quality. For anyone involved in hotel design, construction, or ownership, a deep understanding of this module is not just an asset—it is an absolute necessity. It represents Marriott's promise that behind every warm welcome is a structurally sound and profoundly safe environment, meticulously engineered to protect its most valuable asset: its people. Module 14 devotes six pages to the shower experience

What is remarkable is the regional specialization: the mekhela chador of Assam, the phiran of Kashmir, the lungi of Kerala. This diversity in clothing reflects a lifestyle that honors regional identity even within a unified nation.

Mechanical keys for backup locks must be housed in automated, biometric, or PIN-coded key management cabinets that track who removes a key and when. 5. Cybersecurity and IT Infrastructure Safety Fairfield) / Full Service (e.g.

Guestroom Corridors, Vestibules & Entry Thresholds Brand Application: Select Service (e.g., Courtyard, Fairfield) / Full Service (e.g., Marriott, Sheraton) Version Reference: MDS v2024.10

| Brand Tier | Recirculation Temp | Toilet Type | Shower GPM | Leak Detection | | :--- | :--- | :--- | :--- | :--- | | | 110°F w/ TMV | Dual-flush, concealed | 2.0 GPM (rainshower) | Mandatory, room-level | | Premium (Marriott, Sheraton, Westin) | 110°F w/ balancing valve | Pressure-assisted 1.0 GPF | 1.75 GPM | Mandatory | | Select (Courtyard, SpringHill, Fairfield) | 105°F | Gravity dual-flush 1.28 GPF | 1.75 GPM | Required at vanity only | | Extended Stay (Residence Inn, TownePlace) | 110°F w/ recirc timer | Pressure-assisted | 1.75 GPM | Optional but recommended |

PEX is allowed but only with brass fittings (not plastic push-to-connect). CPVC is banned entirely for hot water lines in full-service hotels. Use Uponor PEX-A with expansion fittings.