NEW VERSION 4 |
Drastically reduces the time required for data analysis and report generation.
Determining the effective refractory period (ERP) of the atria, AV node, or ventricle is fundamental to EP studies. EP Evaluator 12 provides a dedicated refractory period module. Users can mark S1-S2 coupling intervals and automatically visualize where S2 fails to capture. The software calculates ERP, functional refractory period (FRP), and Wenckebach cycles.
: A major enhancement that allows for more flexible method comparison. It supports up to five replicates per instrument for each specimen, significantly improving precision and reducing random bias errors.
: Tools for validating or establishing new lab reference ranges. 3. Running an Experiment ep evaluator 12
EP Evaluator 12 is an essential tool for any clinical laboratory focusing on high-quality patient care, regulatory compliance, and efficient operational performance. By automating complex statistical analyses for validation and verification, it enables laboratorians to confidently implement new methods and maintain the highest standards of accuracy.
Consider a 55-year-old with narrow complex tachycardia, 180 bpm. During the EP study, the real-time recording showed a VA interval of 70 ms—suggestive of typical AVNRT. However, the physician was uncertain due to odd retrograde atrial activation. Later, using EP Evaluator 12, the team reviewed the case with variable speed and filtering. They discovered a subtle eccentric atrial activation (CS 9,10 earlier than CS 1,2) that was missed live. This changed the diagnosis to septal accessory pathway mediated AVRT. The patient underwent successful ablation in a second procedure. Without EP Evaluator 12’s offline analysis, the diagnosis would have remained incorrect.
EP Evaluator 12 is a professional statistical software package from Data Innovations Drastically reduces the time required for data analysis
: Includes new multifunction desktop help buttons and an enhanced networking path log to assist in resolving licensing or connectivity issues in complex lab environments. Core Statistical Modules
EP Evaluator 12 is a specialized laboratory software suite designed to automate clinical method validation and performance verification. It is widely used to ensure laboratory results meet regulatory standards such as CLIA, CAP, and The Joint Commission Data Innovations Key Capabilities and Features Regulatory Compliance
In scar-related VT or accessory pathway localization, pace mapping is essential. The software compares the paced 12-lead ECG morphology with the clinical tachycardia morphology using correlation algorithms (e.g., Pearson’s coefficient). A score of >0.95 suggests the pacing site is close to the arrhythmia origin. EP Evaluator 12 displays these comparisons side-by-side with beat-by-beat alignment, facilitating precise ablation targeting. Users can mark S1-S2 coupling intervals and automatically
Reports are pre-formatted to satisfy requirements for CLIA, CAP, The Joint Commission, and COFRAC .
Medical laboratory scientists use this version to evaluate new instruments, verify assay ranges, and estimate analytical bias. Core Statistical Capabilities
Copyright ©
1996-2002 Fibonacci Trader Corporation. Last updated:
December 28, 2019. All names
mentioned in this document are trademarks or registered trademarks of their respective
owners.