Setting the LIS-SV

This section supplements the “LIS-SV” product manual. The parameters described here are only available if the LIS-SV is used in an ABULiner control unit.

Overview of the 'ABULiner' parameter level

The following parameters can be set in the 'ABULiner' parameter level of the LIS-SV.

Parameter

Designation

See

5.10

Calling up the parameter level

Accessing the 'ABULiner' parameter level

5.11

Activating the LIS-SV for the ABULiner

Activating/deactivating the LIS-SV for the ABULiner

5.11

Setting the gear ratio

Setting the gear ratio

5.12

Activating double lifting speed

Activating double lifting speed on the LIS-SV

5.14

Setting the run-on time of the auxiliary fan

Setting the run-on time of the auxiliary fan

Warnung stürzende Last

Danger during setting work!

During setting work on the LIS-SV, monitoring of the wire rope hoist is switched off. This means the wire rope hoist cannot be monitored for excess load, among other things.  This means the wire rope hoist cannot be monitored for excess load, among other things.

This in turn means the load could fall and kill or injure people!

Do not use the crane for normal work during setting work, and only lift loads very carefully for test purposes!

Accessing the 'ABULiner' parameter level

All LIS-SV parameters which are important for the ABULiner are combined in a separate parameter level, which is shown as a submenu.

chowder capitulos completos en castellano verified

*    Move the load hook out of the limit switch range (up or down).

During parameter setting, the load hook must not be within the limit switch range.

*    Open the menu of the LIS-SV. See the documentation “Load indicator system LIS-SV”.

chowder capitulos completos en castellano verified

Enter button

Arrow buttons

*    Select parameter 5.10.

*    Press ENTER.

●   The 'ABULiner' parameter level is activated.

●   Parameter 5.11 is displayed.

Exiting the 'ABULiner' parameter level

chowder capitulos completos en castellano verified

Enter button

Arrow buttons

*    Select parameter 5.99.

*    Press ENTER.

●   The previous parameter level is reactivated.

●   Parameter 5.10 is displayed.

Activating/deactivating the LIS-SV for the ABULiner

The LIS-SV is automatically activated for the ABULiner if a value is entered for the parameter 5.11.

In the ABULiner mode (a value is set for parameter 5.11):

─     The LIS-SV can monitor the total load for a maximum of two wire rope hoists.

─     Input F3 (normally used for measuring the load of wire rope hoist 3) now serves in monitoring the current rotational frequency of the hoist motor.

─     A value can be entered for parameter 3.0 (maximum load capacity of wire rope hoist 3). If a value is entered for this, parameter 5.11 cannot be set.

─     This interlocking thus excludes an incorrect setting.

─     The load-controlled switching point at output TxD of the LIS-SV cannot be used.

─     Parameter 4.5 (setting for load-controlled switching point) is not available.

In the normal mode (no value is set for parameter 5.11):

─     Operation of the ABULiner Lifting/Lowering unit is not possible.

─     The LIS-SV can monitor the total load for up to three wire rope hoists.

─     Input F3 serves in measuring the load of a third wire rope hoist.

─     A value can be entered for parameter 5.11 (gear ratio). If a value is entered for this, parameter 3.0 cannot be set.

─     This interlocking thus excludes an incorrect setting.

─     The load-controlled switching point at output TxD of the LIS-SV can be used.

─     Parameter 4.5 (setting for load-controlled switching point) can be used.

Setting the gear ratio

The LIS-SV uses the signal of the encoder and the gear ratio of the hoisting gear to calculate the hook travel distance, the maximum distance in the limit switch range and the current rotational frequency of the hoist motor. The gear ratio must be set on the machine.

chowder capitulos completos en castellano verified

Cable speed

*    Read off the type designation at the type plate of the wire rope hoist.

*    Read off the cable speed.

*    From this table, select the gear ratio that matches the cable speed.

Cable speed

Hoist motor GM

32 m/min at 50 Hz
38 m/min at 60 Hz

25 m/min at 50 Hz
30 m/min at 60 Hz

20 m/min at 50 Hz
24 m/min at 60 Hz

16 m/min at 50 Hz
19 m/min at 60 Hz

800.4

50.01

63.49

77.77

98.16

800.5

47.03

60.04

74.66

95.03

1000.6

54.43

68.91

84.00

105.1

1000.7

54.60

68.06

81.45

104.6

2000.3

58.22

74.23

91.19

118.4

3000.4

73.61

93.92

118.4

152.9

5000.3

85.14

109.3

132.8

169.0

5000.4

80.20

104.9

127.7

160.6

6000.3

94.69

118.5

149.6

182.7

7000.1

118.0

148.3

182.6

232.0

Table: Gear ratios (numerical values) depending on hoist motor (lines) and cable speeds (columns) at 50 and 60 Hz.

chowder capitulos completos en castellano verified

Enter button

Arrow buttons

*    Move the load hook out of the limit switch range (up or down).

During parameter setting, the load hook must not be within the limit switch range.

*    Select parameter 5.11.

*    Press ENTER.

●   The set value is displayed.

If the value is 0.00, the function is deactivated.

●   Hold ENTER pressed.

●   CODE is displayed.

*    Hold ENTER pressed.

chowder capitulos completos en castellano verified

Enter button

Arrow buttons

*    Enter the code 1443.

*    Press ENTER briefly.

chowder capitulos completos en castellano verified

Enter button

Arrow buttons

*    Set the value from the table.

If the display ‘0.00’ cannot be changed, a value is set in parameter 3.0.  In this case, set the value to zero first.

*    Press ENTER briefly.

Chowder Capitulos Completos En Castellano Verified !!install!!

¿Recuerdas de ese capítulo?

Muchos sitios usan la palabra "verified" (verificado) como gancho publicitario para ocultar archivos ejecutables maliciosos o extensiones de navegador peligrosas.

¿Estás buscando una para repasarla entera?

: Tienes disponible la Temporada 1 para compra y visualización en cualquier dispositivo Android o iOS. Resumen de Episodios chowder capitulos completos en castellano verified

2. Formatos Físicos y Tiendas Digitales (Apple TV / Google Play)

: This is currently the primary home for Chowder globally. However, availability of the Castilian Spanish track depends on your specific region (Europe/Spain).

Era un día inusualmente caluroso en Ciudad Mazapán, de esos días en los que el aire huele a caramelo quemado y las sombras parecen querer derretirse sobre el pavimento de jengibre. En la cocina del Catering Mung Daal, el joven ¿Recuerdas de ese capítulo

La serie animada Chowder , creada por C.H. Greenblatt para Cartoon Network, se convirtió en un clásico de la animación gracias a su humor surrealista, técnicas mixtas de animación y constantes rupturas de la cuarta pared. Si estás buscando revivir las locuras de este peculiar aprendiz de cocina en Ciudad Mazapán de forma legal, segura y con calidad de audio verificada en castellano (español de España), esta guía te mostrará las mejores opciones actuales.

En algunas regiones, plataformas como permiten comprar temporadas completas o episodios sueltos de Cartoon Network. Una vez comprados, los capítulos son tuyos para siempre en tu biblioteca digital con la máxima fidelidad de audio en castellano.

Chowder está disponible en castellano en versiones oficiales según país y acuerdos de distribución; para obtener "capítulos completos en castellano verificados" lo más seguro es usar plataformas oficiales, tiendas digitales o emisiones autorizadas. Verifica la pista de audio, la calidad y la procedencia para asegurarte de que el episodio sea legítimo. : Tienes disponible la Temporada 1 para compra

: Ofrece episodios individuales y temporadas completas en castellano.

De repente, los ojos de Chowder se iluminaron como dos faros. Su cuerpo empezó a vibrar y, antes de que Mung Daal pudiera detenerlo, el pequeño aprendiz empezó a correr por las paredes de la cocina, dejando una estela de electricidad estática a su paso.

9 episodios (2009–2010) — Incluye el gran desenlace de la serie, "Chowder crece".

Chowder: ¡Disfruta de los capítulos completos en castellano verificado!

Para disfrutar de la serie con la mejor calidad de audio y video, libre de publicidad engañosa o malware, las vías oficiales son la opción recomendada.

Only for auxiliary fans

Setting the run-on time of the auxiliary fan

The auxiliary fan of the hoist motor continues to run for several minutes after the lifting or lowering. This ensures that the hoist motor is adequately cooled even at slow lifting speeds. The run-on time can be adjusted.

chowder capitulos completos en castellano verified

Enter button

Arrow buttons

*    Move the load hook out of the limit switch range (up or down).

During parameter setting, the load hook must not be within the limit switch range.

*    Select parameter 5.14.

*    Press ENTER.

●   The set value is displayed.

chowder capitulos completos en castellano verified

Enter button

*    Set the value to between 3 and 10 minutes using the arrow buttons.

*    Press ENTER.